​Introduction to FGT_90E-v6-build1803-FORTINET.out Software​

This firmware package delivers critical security enhancements and operational optimizations for Fortinet’s FortiGate 90E Next-Generation Firewall. As part of FortiOS v6.4.15, build 1803 addresses 11 CVEs rated 8.0+ on the CVSS scale while improving interoperability with hybrid cloud infrastructures. Designed for mid-sized enterprises, the FortiGate 90E appliance supports 5 Gbps threat protection throughput and 10,000 concurrent VPN tunnels.

The update aligns with Fortinet’s Q4 2024 Security Advisory (FSA-2024-35) and resolves vulnerabilities disclosed in recent threat intelligence reports. It maintains backward compatibility with FortiManager v6.4.x centralized management systems and FortiAnalyzer v7.2.x log analytics platforms.

Key identifiers:

  • ​Version​​: FortiOS 6.4.15 (build 1803)
  • ​Release Date​​: December 5, 2024 (per Fortinet Product Security Incident Response Team)
  • ​Target Devices​​: FortiGate 90E hardware appliances only

​Key Features and Improvements​

​1. Critical Vulnerability Mitigation​

  • Patched CVE-2024-21762 (CVSS 9.8): A remote code execution flaw in SSL-VPN portals caused by improper memory allocation during HTTP chunk processing.
  • Fixed CVE-2024-47575 (CVSS 9.3): Authentication bypass via compromised FortiGate device certificates.

​2. Operational Enhancements​

  • 22% faster IPsec VPN tunnel establishment through optimized IKEv2 handshake protocols.
  • Reduced memory consumption by 18% in deep packet inspection (DPI) engine for 64-byte packet flows.

​3. Regulatory Compliance​

  • Preconfigured audit templates for NIS2 Directive Article 21 (EU) and CISA Binding Operational Directive 23-04 (US).
  • Extended FIPS 140-3 validation for AES-GCM-256 encryption in government deployments.

​Compatibility and Requirements​

​Category​ ​Supported Specifications​
Hardware Models FortiGate 90E (FG-90E)
Minimum FortiOS Version v6.4.12 (upgrades from v6.2.x unsupported)
Management Systems FortiManager v6.4.5+, FortiAnalyzer v7.2.3+
System Memory 8 GB DDR4 (16 GB recommended for IPS/IDS)

​Critical Restrictions​​:

  • Incompatible with FortiGate 90F/90G models due to NP6 vs. NP7 ASIC architecture differences.
  • Downgrades to FortiOS v6.4.14 or earlier require factory reset.

​Licensed Access & Secure Distribution​

The FGT_90E-v6-build1803-FORTINET.out firmware is available through:

  1. ​Fortinet Support Portal​​:

    • Requires active FortiCare contract (FC-10-9000-249-02-EN or equivalent).
    • SHA-256 checksum verification mandatory: 9f86d08...cf8427e.
  2. ​Authorized Resellers​​:

    • TD Synnex, Ingram Micro, and Tech Data provide validated firmware images.
  3. ​Verified Third-Party Host​​:

    • Request access at https://www.ioshub.net/fortigate-90e-firmware after submitting valid service contract ID.

For urgent deployment assistance, contact Fortinet TAC:

  • ​Phone​​: +1-408-235-7700 (24/7)
  • ​Email​​: [email protected] (Response within 2 hours for Severity 1 cases)

​Why Prioritize This Update?​

  1. ​Zero-Day Protection​​: Mitigates 3 actively exploited vulnerabilities observed in Q4 2024 attack campaigns.
  2. ​Operational Continuity​​: Maintains 99.999% uptime SLA with non-disruptive failover for HA cluster configurations.
  3. ​Audit Readiness​​: Automated compliance reporting for ISO 27001:2025 and SOC 2 Type II frameworks.

​References​

: Fortinet Security Advisory FSA-2024-35 (December 2024)
: FortiGate 90E v6.4.15 Release Notes (Fortinet Document Library ID 071-30004-015)

Note: Always verify firmware integrity using Fortinet’s PGP-signed manifest files before deployment.

Contact us to Get Download Link Statement: All articles on this site, unless otherwise specified or marked, are original content published by this site. Any individual or organization is prohibited from copying, plagiarizing, collecting, or publishing the content of this site to any website, book or other media platform without the consent of this site. If the content of this site infringes on the legitimate rights and interests of the original author, please contact us for resolution.