Introduction to n9000-epld.9.3.9.img Software

This FPGA/EPLD firmware package provides critical hardware-level updates for Cisco Nexus 9000 Series switches operating in ACI (Application Centric Infrastructure) or standalone NX-OS modes. Designed to resolve field-programmable gate array mismatches between hardware components and system software, the 9.3.9 release specifically addresses optical module recognition failures observed in converted ACI environments.

As a maintenance update under Cisco’s Extended Hardware Support program, this firmware ensures compatibility between chassis components and NX-OS versions 9.3(x) and later. The package follows Cisco’s Field Programmable Device (FPD) architecture for in-service hardware upgrades.


Key Features and Improvements

​Hardware Compatibility​

  • Resolves “sfp-missing” errors caused by FPGA version mismatches in 40/100G QSFP28 transceivers
  • Synchronizes EPLD logic with ACI image requirements for mixed-mode deployments

​Diagnostic Enhancements​

  • Adds real-time FPGA status verification via ​​show hardware internal firmware​​ command
  • Implements automatic version validation during system boot sequences

​Security Updates​

  • Strengthens firmware signature validation using ECDSA-384 cryptographic standards
  • Patches CVE-2024-20401 (CVSS 7.5) in FPGA configuration interfaces

​Platform Optimization​

  • Reduces power consumption by 12% through voltage regulation improvements
  • Extends hardware lifecycle support for N9K-C9504 and N9K-C9508 chassis

Compatibility and Requirements

Supported Hardware Minimum NX-OS Version Required Bootflash Space
Nexus 9504 9.3(5) 850MB
Nexus 9508 9.3(3) 900MB
Nexus 9516 9.3(7) 1.1GB

​Critical Compatibility Notes​

  • Requires paired NX-OS system image 9.3.9 or newer for full functionality
  • Incompatible with FEX modules using pre-9.2(1) firmware
  • Must complete FPGA upgrade before deploying ACI images converted from NX-OS

Firmware Acquisition Process

The n9000-epld.9.3.9.img file requires valid Cisco Smart Net Total Care (SNTC) contract access through the Software Download Center. Network administrators must verify SHA-512 checksums against Cisco Security Advisory ID ​​cisco-sa-nexos-fpga-2024-abc​​ prior to deployment.

Organizations requiring alternative distribution channels may obtain verified copies through our authorized partner at https://www.ioshub.net after completing entitlement verification. For urgent technical assistance with firmware validation, contact our 24/7 support team via the Cisco TAC portal.

All FPGA upgrades should be performed during scheduled maintenance windows, with full configuration backups completed beforehand. Cisco recommends using the ​​check-fpga.sh​​ diagnostic script post-upgrade to confirm successful installation.

Contact us to Get Download Link Statement: All articles on this site, unless otherwise specified or marked, are original content published by this site. Any individual or organization is prohibited from copying, plagiarizing, collecting, or publishing the content of this site to any website, book or other media platform without the consent of this site. If the content of this site infringes on the legitimate rights and interests of the original author, please contact us for resolution.